产品中心/Product Center
*注:按产品型号,可检索常见问答、样本、证书等信息。

Modular DIN energy meters    订购编号:

点击这里发送询价

请详细填写一下内容,包括产品原产国、品牌完整名称以及您所能得到的所有信息,这将有助于我们准确迅速的报价。非常感谢!

品牌厂商(Manutacturer)*

公司名称*

产品名称(Product Name)*

联系人*

产品型号(Product Type)*

联系地址*

产品序列号(ID-Nr;Artikel-Nr)

联系电话*

产品描述(Voltage,Amp,Kw,Rpm)

传真*

需求数量(Quantity demanded)

联系邮箱*

附加信息,更具体要求

Modular DIN energy meters
There are 20 products.
 Code Description Model Tech. Note Manual Stock  
CE21175A0

Direct connected active energy meter (class 1) - Main: single-phase - Format: 2 DIN module - Output: without - Current: 5 (36) A - direct - Voltage: 230...240 V - direct - Aux: Selfsupplied

CONTO D2-b    
CE4DT06A2

Multifunction direct connected active (class 1) and reactive (class 2) energy meter - Main: three-phase 4 wire unbalanced load - Format: 4 DIN module - Output: pulses (Wh or varh) - Current: 10 (63) A - direct - Voltage: 190…440 V (phase-phase) - direct - Aux: Selfsupplied

CONTO D4-Pd  
CE4DT06A4

Multifunction direct connected active (class 1) and reactive (class 2) energy meter - Main: three-phase 4 wire unbalanced load - Format: 4 DIN module - Output: RS485 communication, protocol JBUS/MODBUS - Current: 10 (63) A - direct - Voltage: 190…440 V (phase-phase) - direct - Aux: Selfsupplied

CONTO D4-Pd  
CE4DT12A2

Multifunction CT connected active (class 1) and reactive (class 2) energy meter - Main: single or three-phase 3/4 wire balanced or unbalanced load - Format: 4 DIN module - Output: pulses (Wh or varh) - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…150 V (phase-phase) - from VT (programmable ratio) - Aux: Selfsupplied

CONTO D4-Pt  
CE4DT12A4

Multifunction CT connected active (class 1) and reactive (class 2) energy meter - Main: single or three-phase 3/4 wire balanced or unbalanced load - Format: 4 DIN module - Output: RS485 communication, protocol JBUS/MODBUS - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…150 V (phase-phase) - from VT (programmable ratio) - Aux: Selfsupplied

CONTO D4-Pt    
CE4DT12A6

Multifunction CT connected active (class 1) and reactive (class 2) energy meter - Main: single or three-phase 3/4 wire balanced or unbalanced load - Format: 4 DIN module - Output: pulses (Wh o varh)+RS485 communication, protocol JBUS/MODBUS - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…150 V (phase-phase) - from VT (programmable ratio) - Aux: Selfsupplied

CONTO D4-Pt    
CE4DT14A2

Multifunction CT connected active (class 1) and reactive (class 2) energy meter - Main: single or three-phase 3/4 wire balanced or unbalanced load - Format: 4 DIN module - Output: pulses (Wh or varh) - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 190…440 V (phase-phase) - direct - Aux: Selfsupplied

CONTO D4-Pt  
CE4DT14A4

Multifunction CT connected active (class 1) and reactive (class 2) energy meter - Main: single or three-phase 3/4 wire balanced or unbalanced load - Format: 4 DIN module - Output: RS485 communication, protocol JBUS/MODBUS - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 190…440 V (phase-phase) - direct - Aux: Selfsupplied

CONTO D4-Pt  
CE4DT14A6

Multifunction CT connected active (class 1) and reactive (class 2) energy meter - Main: single or three-phase 3/4 wire balanced or unbalanced load - Format: 4 DIN module - Output: pulses (Wh o varh)+RS485 communication, protocol JBUS/MODBUS - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 190…440 V (phase-phase) - direct - Aux: Selfsupplied

CONTO D4-Pt  
CE4DT12AM

Multifunction CT connected active (class 1) and reactive (class 2) energy meter - Main: single or three-phase 3/4 wire balanced or unbalanced load - Format: 4 DIN module - Output: pulses (Wh o varh)+communication M-Bus - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…150 V (phase-phase) - from VT (programmable ratio) - Aux: Selfsupplied

CONTO D4-Pt    
CE4DT14AM

Multifunction CT connected active (class 1) and reactive (class 2) energy meter - Main: single or three-phase 3/4 wire balanced or unbalanced load - Format: 4 DIN module - Output: pulses (Wh o varh)+communication M-Bus - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 190…440 V (phase-phase) - direct - Aux: Selfsupplied

CONTO D4-Pt    
CE4DT06AM

Multifunction direct connected active (class 1) and reactive (class 2) energy meter - Main: three-phase 3/4 wire unbalanced load - Format: 4 DIN module - Output: communication M-Bus - Current: 10 (63) A - direct - Voltage: 190…440 V (phase-phase) - direct - Aux: Selfsupplied

CONTO D4-Pd    
CE20195A2

Multifunction direct connected active energy meter (class 1) - Main: single-phase - Format: 2 DIN module - Output: pulses (Wh) - Current: 5 (63) A - direct - Voltage: 230...240 V - direct - Aux: Selfsupplied

CONTO D2  
CE20195A4

Multifunction direct connected active energy meter (class 1) - Main: single-phase - Format: 2 DIN module - Output: RS485 communication, protocol JBUS/MODBUS - Current: 5 (63) A - direct - Voltage: 230...240 V - direct - Aux: Selfsupplied

CONTO D2  
CE11165A0

Direct connected active energy meter (class 1) - Main: single-phase - Format: 1 DIN module - Output: without - Current: 5 (32) A - direct - Voltage: 230 V - direct - Aux: Selfsupplied

CONTO D1    
CE11165A2

Direct connected active energy meter (class 1) - Main: single-phase - Format: 1 DIN module - Output: pulses (Wh) - Current: 5 (32) A - direct - Voltage: 230 V - direct - Aux: Selfsupplied

CONTO D1  
CE11165A4

Direct connected active energy meter (class 1) - Main: single-phase - Format: 1 DIN module - Output: RS485 communication - Current: 5 (45) A - direct - Voltage: 230 V - direct - Aux: Selfsupplied

CONTO D1  
CE4DT36A4

Multifunction direct connected active (class 1) and reactive (class 2) energy meter - Main: 3 single-phase network with common neutral - Format: 4 DIN module - Output: RS485 communication, protocol JBUS/MODBUS - Current: 10 (63) A - direct - Voltage: 230 V - direct - Aux: Selfsupplied

CONTO D4-Pd    
CE4DT06A23F

Multifunction direct connected active (class 1) and reactive (class 2) energy meter - Main: three-phase 3 wire unbalanced load - Format: 4 DIN module - Output: pulses (Wh or varh) - Current: 10 (63) A - direct - Voltage: 190…440 V (phase-phase) - direct - Aux: Selfsupplied

CONTO D4-Pd    
CE4DT06A43F

Multifunction direct connected active (class 1) and reactive (class 2) energy meter - Main: three-phase 3 wire unbalanced load - Format: 4 DIN module - Output: RS485 communication, protocol JBUS/MODBUS - Current: 10 (63) A - direct - Voltage: 190…440 V (phase-phase) - direct - Aux: Selfsupplied

CONTO D4-Pd