Flush mounting network monitors for a.c.

There are 22 products.
 Code Description Model Tech. Note Manual Stock  
MF7GM0008A

Network monitor for l.v. application - Main: single-phase or three-phase 4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: without - Current: 1 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 340…450 V (phase-phase) - direct - Aux: Selfsupplied

Nemo 72-b    
MF7GM0009A

Network monitor for l.v. application - Main: single-phase or three-phase 4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: without - Current: 5 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 340…450 V (phase-phase) - direct - Aux: Selfsupplied

Nemo 72-b  
MF7GM2008A

Network monitor for l.v. application - Main: single-phase or three-phase 4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: 2 alarm relays - Current: 1 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 340…450 V (phase-phase) - direct - Aux: Selfsupplied

Nemo 72-b    
MF7GM2009A

Network monitor for l.v. application - Main: single-phase or three-phase 4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: 2 alarm relays - Current: 5 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 340…450 V (phase-phase) - direct - Aux: Selfsupplied

Nemo 72-b    
MF7GT0008A

Network monitor for l.v. application - Main: three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: without - Current: 1 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 340…450 V (phase-phase) - direct - Aux: Selfsupplied

Nemo 72-b    
MF7GT0009A

Network monitor for l.v. application - Main: three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: without - Current: 5 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 340…450 V (phase-phase) - direct - Aux: Selfsupplied

Nemo 72-b  
MF7GT2008A

Network monitor for l.v. application - Main: three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: 2 alarm relays - Current: 1 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 340…450 V (phase-phase) - direct - Aux: Selfsupplied

Nemo 72-b    
MF7GT2009A

Network monitor for l.v. application - Main: three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: 2 alarm relays - Current: 5 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 340…450 V (phase-phase) - direct - Aux: Selfsupplied

Nemo 72-b  
MF96001

Network monitor for l.v. application with active (cl.0,5) and reactive (cl.2) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 96x96 mm - Output: for 4 plug-in optional modules - Current: 1 and 5 A - from dedicated CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 80…265 Vac/110…300 Vdc

Nemo 96HD  
MF96002

Network monitor for l.v. application with active (cl.0,5) and reactive (cl.2) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 96x96 mm - Output: for 4 plug-in optional modules - Current: 1 and 5 A - from dedicated CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 11…60 Vdc

Nemo 96HD  
MF96021

Network monitor for l.v./m.v applications with active (cl.0,5) and reactive (cl.2) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 96x96 mm - Output: for 4 plug-in optional modules - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…690 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 80…265 Vac/110…300 Vdc

Nemo 96HD+  
MF96022

Network monitor for l.v./m.v applications with active (cl.0,5) and reactive (cl.2) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 96x96 mm - Output: for 4 plug-in optional modules - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…690 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 11…60 Vdc

Nemo 96HD+  
MF96411

Network monitor for l.v. application with active energy count and harmonic analysis up to the 50th - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 96x96 mm - Output: pulses (Wh or varh) - Current: 1 and 5 A - from dedicated CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 80…265 Vac/110…300 Vdc

Nemo 96HDLe  
MF96412

Network monitor for l.v. application with active energy count and harmonic analysis up to the 50th - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 96x96 mm - Output: pulses (Wh or varh) - Current: 1 and 5 A - from dedicated CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 11…60 Vdc

Nemo 96HDLe    
MF96421

Network monitor for l.v. application with active energy count and harmonic analysis up to the 50th - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 96x96 mm - Output: pulses (Wh o varh)+RS485 communication, protocol JBUS/MODBUS - Current: 1 and 5 A - from dedicated CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 80…265 Vac/110…300 Vdc

Nemo 96HDLe  
MF96422

Network monitor for l.v. application with active energy count and harmonic analysis up to the 50th - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 96x96 mm - Output: pulses (Wh o varh)+RS485 communication, protocol JBUS/MODBUS - Current: 1 and 5 A - from dedicated CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 11…60 Vdc

Nemo 96HDLe    
MF72411

Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: S0 Pulse output or 1 alarm contact - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 80…265 Vac/110…300 Vdc

Nemo 72-Le  
MF72412

Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: S0 Pulse output or 1 alarm contact - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 20...60 Vdc

Nemo 72-Le    
MF72421

Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: S0 Pulse output or 1 alarm contact + RS485 Modbus RTU/TCP protocol - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 80…265 Vac/110…300 Vdc

Nemo 72-Le  
MF72422

Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: S0 Pulse output or 1 alarm contact + RS485 Modbus RTU/TCP protocol - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 20...60 Vdc

Nemo 72-Le    
MF724B1

Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: S0 Pulse output or 1 alarm contact + RS485 BACNET protocol - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 80…265 Vac/110…300 Vdc

Nemo 72-Le  
MF724B2

Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 72x72 mm - Output: S0 Pulse output or 1 alarm contact + RS485 BACNET protocol - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 20...60 Vdc

Nemo 72-Le