Code |
Description |
Model |
Tech. Note |
Manual |
Stock |
|
MF6GT00063 |
Network monitor for l.v. application - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: without - Current: 1 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 80…600 V (phase-phase) - direct - Aux: 115 Vac
|
Nemo D4-b |
|
|
|
|
MF6GT00066 |
Network monitor for l.v. application - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: without - Current: 1 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 80…600 V (phase-phase) - direct - Aux: 230...240 Vac
|
Nemo D4-b |
|
|
|
|
MF6GT00069 |
Network monitor for l.v. application - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: without - Current: 1 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 80…600 V (phase-phase) - direct - Aux: 400 Vac
|
Nemo D4-b |
|
|
|
|
MF6GT00073 |
Network monitor for l.v. application - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: without - Current: 5 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 80…600 V (phase-phase) - direct - Aux: 115 Vac
|
Nemo D4-b |
|
|
|
|
MF6GT00076 |
Network monitor for l.v. application - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: without - Current: 5 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 80…600 V (phase-phase) - direct - Aux: 230...240 Vac
|
Nemo D4-b |
|
|
|
|
MF6GT00079 |
Network monitor for l.v. application - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: without - Current: 5 A - from CT 5…8000A (41 selectable primary ranges) - Voltage: 80…600 V (phase-phase) - direct - Aux: 400 Vac
|
Nemo D4-b |
|
|
|
|
MF6HT40003 |
Network monitor for l.v./m.v applications with active (cl.1) and reactive (cl.2) energy count - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: pulses (Wh o varh)+RS485 communication, protocol JBUS/MODBUS - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…480 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 115 Vac
|
Nemo D4-L+ |
|
|
|
|
MF6HT40006 |
Network monitor for l.v./m.v applications with active (cl.1) and reactive (cl.2) energy count - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: pulses (Wh o varh)+RS485 communication, protocol JBUS/MODBUS - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…480 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 230...240 Vac
|
Nemo D4-L+ |
|
|
|
|
MF6HT4000H |
Network monitor for l.v./m.v applications with active (cl.1) and reactive (cl.2) energy count - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: pulses (Wh o varh)+RS485 communication, protocol JBUS/MODBUS - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…480 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 20...150 Vdc/48 Vac
|
Nemo D4-L+ |
|
|
|
|
MF6HTU0003 |
Network monitor for l.v./m.v applications with active (cl.1) and reactive (cl.2) energy count - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: pulses (Wh or varh) - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…480 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 115 Vac
|
Nemo D4-L+ |
|
|
|
|
MF6HTU0006 |
Network monitor for l.v./m.v applications with active (cl.1) and reactive (cl.2) energy count - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: pulses (Wh or varh) - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…480 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 230...240 Vac
|
Nemo D4-L+ |
|
|
|
|
MF6HTU000H |
Network monitor for l.v./m.v applications with active (cl.1) and reactive (cl.2) energy count - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: pulses (Wh or varh) - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…480 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 20...150 Vdc/48 Vac
|
Nemo D4-L+ |
|
|
|
|
MF6HTB000H |
Network monitor for l.v./m.v applications with active (cl.1) and reactive (cl.2) energy count - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: RS485 communication, protocol BACNET - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…480 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 20...150 Vdc/48 Vac
|
Nemo D4-L+ |
|
|
|
|
MF6HTB0003 |
Network monitor for l.v./m.v applications with active (cl.1) and reactive (cl.2) energy count - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: RS485 communication, protocol BACNET - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…480 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 115 Vac
|
Nemo D4-L+ |
|
|
|
|
MF6HTB0006 |
Network monitor for l.v./m.v applications with active (cl.1) and reactive (cl.2) energy count - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: RS485 communication, protocol BACNET - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…480 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 230...240 Vac
|
Nemo D4-L+ |
|
|
|
|
MFD4411 |
Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: S0 Pulse output or 1 alarm contact - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 80…265 Vac/110…300 Vdc
|
Nemo D4-Le |
|
|
|
|
MFD4421 |
Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: S0 Pulse output or 1 alarm contact + RS485 Modbus RTU/TCP protocol - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 80…265 Vac/110…300 Vdc
|
Nemo D4-Le |
|
|
|
|
MFD44B1 |
Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: S0 Pulse output or 1 alarm contact + RS485 BACNET protocol - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 80…265 Vac/110…300 Vdc
|
Nemo D4-Le |
|
|
|
|
MFD4412 |
Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: S0 Pulse output or 1 alarm contact - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 11…60 Vdc
|
Nemo D4-Le |
|
|
|
|
MFD4422 |
Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: S0 Pulse output or 1 alarm contact + RS485 Modbus RTU/TCP protocol - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 11…60 Vdc
|
Nemo D4-Le |
|
|
|
|
MFD44B2 |
Network monitor for l.v. application with active (cl.0,5) and reactive (cl.1) energy count on 4 quadrants - Main: single-phase or three-phase 3/4 wire unbalanced load - Display: LCD rear-lighted - Format: 4 DIN module - Output: S0 Pulse output or 1 alarm contact + RS485 BACNET protocol - Current: 1 and 5 A - from CT (programmable ratio) - Voltage: 80…500 V (phase-phase) - direct or from VT (programmable ratio) - Aux: 11…60 Vdc
|
Nemo D4-Le |
|
|
|
|