Code |
Description |
Model |
Tech. Note |
Manual |
Stock |
|
TN2P1PA11A |
Active power separate accessories for analogue meters - Main: single-phase - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 100 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P1PA12A |
Active power separate accessories for analogue meters - Main: single-phase - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 100 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P1PA21A |
Active power separate accessories for analogue meters - Main: single-phase - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 110 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P1PA22A |
Active power separate accessories for analogue meters - Main: single-phase - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 110 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P1PA31A |
Active power separate accessories for analogue meters - Main: single-phase - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 230 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P1PA32A |
Active power separate accessories for analogue meters - Main: single-phase - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 230 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P1PA41A |
Active power separate accessories for analogue meters - Main: single-phase - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 240 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P1PA42A |
Active power separate accessories for analogue meters - Main: single-phase - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 240 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P2PA11A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 100 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P2PA12A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 100 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P2PA21A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 110 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P2PA22A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 110 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P2PA51A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 400 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P2PA52A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 400 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P2PA61A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 415 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P2PA62A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 415 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P3PA11A |
Active power separate accessories for analogue meters - Main: three-phase 4 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 100 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P3PA12A |
Active power separate accessories for analogue meters - Main: three-phase 4 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 100 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P3PA21A |
Active power separate accessories for analogue meters - Main: three-phase 4 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 110 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P3PA22A |
Active power separate accessories for analogue meters - Main: three-phase 4 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 110 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P3PA51A |
Active power separate accessories for analogue meters - Main: three-phase 4 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 400 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P3PA52A |
Active power separate accessories for analogue meters - Main: three-phase 4 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 400 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P3PA61A |
Active power separate accessories for analogue meters - Main: three-phase 4 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 415 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P3PA62A |
Active power separate accessories for analogue meters - Main: three-phase 4 wire balanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 415 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P4PA11A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire unbalanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 100 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P4PA12A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire unbalanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 100 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P4PA21A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire unbalanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 110 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P4PA22A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire unbalanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 110 V - Aux: Selfsupplied - Code completion: specify CT ratio, VT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P4PA51A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire unbalanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 1 A - Voltage: 400 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|
TN2P4PA52A |
Active power separate accessories for analogue meters - Main: three-phase 3 wire unbalanced load - Format: 4 DIN module - Measure range: -P...0...+P - Output: 1...0...1 mA - Current: 5 A - Voltage: 400 V - Aux: Selfsupplied - Code completion: specify CT ratio and measuring range corresponding to output
|
Tesi P |
|
|
|
|